SmarTherm Solar

Features & Benefits
The Joule Smartherm Twin Solar unvented cylinder is an ideal solution for big domestic or commercial solar applications. The units is designed and manufactured with all connections and gauges to allow control and a clean and professional installation.
Categories: SmarTherm
General
Item Code; | |||||
6bar. | TCFMVSX0300LFC | TCFMVSX0400LFC | TCFMVSX0500LFC | TCFMVSX0800LFC | TCFMVSX1000LFC |
Solar | 300 | 400 | 500 | 800 | 1000 |
Titanium Imm. – Fact. Fitted As Std. | 2 x 3kW | 2 x 3kW | 2 x 3kW | 2 x 3kW | 2 x 3kW |
Primary Coul Surface Area (m2) | 1.21 | 1.21 | 1.21 | 2.86 | 2.86 |
Prim. Coil Rating @ 60L/m 80ºC (kW) | 46 | 46 | 46 | 73 | 73 |
Coils (Prim & Solar) – Max. Pressure (bar) | 6 | 6 | 6 | 6 | 6 |
Dedicated Solar Volume (ltr) | 113.1 | 153.3 | 197.9 | 307.9 | 460.8 |
Solar Coil Surface Area (m2) | 1.1 | 1.1 | 1.1 | 2.0 | 2.0 |
Coil Diameter (Both Coils) | 32 | 32 | 32 | 38 | 38 |
Solar Coil Rating @ 60L/m (kW) | 43 | 43 | 43 | 57 | 57 |
Inspection Flange | Optional – for inspection only – CANNOT be used with flanged immersion heaters |
Performance | 300 | 400 | 500 | 800 | 1000 |
Hot Water Capacity (ltr) | 278.5 | 377 | 483 | 732 | 1063 |
Heat Up Time (ΔT 50°C) | 35 | 46 | 58 | 71 | 89 |
1º Re-Heat time (70% draw off) 60L/min | 11 | 15 | 21 | 28 | 34 |
1º Re-Heat time (70% draw off) 30L/min | 16 | 21 | 29 | 40 | 48 |
1º Re-Heat time (70% draw off) 15L/min | 24 | 38 | 47 | 71 | 81 |
Weight Empty (kg) | 88 | 89 | 105.5 | 240 | 250 |
Weight Full (kg) | 366.5 | 466 | 588 | 972 | 1313 |
Prim. Coil Surf. Area (m2) | 1.21 | 1.21 | 1.21 | 2.86 | 2.86 |
Prim. Coil Rating @ 60L/min (kW) | 46 | 46 | 46 | 73 | 73 |
Prim. Coil Rating @ 30L/min (kW) | 36.72 | 36.72 | 36.72 | 50 | 50 |
Prim. Coil Rating @ 15L/min (kW) | 21 | 21 | 21 | 31 | 31 |
Prim. Coil Press. Drop @ 15L/min (mbar) | 19 | 19 | 19 | 16 | 16 |
Prim. Coil Press. Drop @ 30L/min (mbar) | 29 | 29 | 29 | 65 | 65 |
Prim. Coil Press. Drop @ 60L/min (mbar) | 245 | 245 | 245 | 335 | 335 |
Dedicated Solar Volume (ltr) | 113.1 | 153.3 | 197.9 | 307.9 | 460.8 |
Solar Coil Surface Area (m2) | 1.1 | 1.1 | 1.1 | 2 | 2 |
Solar Coil Rating @ 60L/min (kW) | 43 | 43 | 43 | 57 | 57 |
Cont. Output @ 60ºC ΔT 50°C (L/hr) | 453 | 453 | 453 | 1110 | 1110 |
All Cylinders – 3 & 6 bar | 300 | 400 | 500 | 800 | 1000 |
Diameter (mm) | 620 | 710 | 710 | 920 | 1100 |
Height (mm) | 1670 | 1670 | 2030 | 2050 | 2170 |
Hot And Cold Connections BSP F | 1.5” | 1.5” | 1.5” | 2.0” | 2.0” |
Coil Conn. (+for the solar coil) BSP F | 1.5” | 1.5” | 1.5” | 1.5” | 1.5” |
Secondary Return BSP F | 1.25” | 1.25” | 1.25” | 1.25” | 1.25” |
Max. Op. Pressure – 3/6 bar kit (bar) | 6 / 10 | 6 / 10 | 6 / 10 | 6 / 10 | 6 / 10 |
T&P Setting 3/6 bar kit (bar) | 7 / 10 | 7 / 10 | 7 / 10 | 7 / 10 | 7 / 10 |
T&P Size – Multi Energy / Indirect+Solar | 1.0” / 0.75” | 1.0” / 0.75” | 1.0” / 0.75” | 1.0” / 0.75” | 1.25” / 0.75” |
Cold W. Safety Devices – PRV, ERV, Chk Vlv | 1.0” (one piece) | 1.25” (multi-piece) | |||
Exp. Relief Valve Setting – 3/6 bar kit (bar) | 6 / 8 | 6 / 8 | 6 / 8 | 6 / 8 | 6 / 8 |
2-port Mot. Valve (Indirect & Solar Only) | 28mm | 28mm | 28mm | 28mm | 1.25” |
2-port Mot. Valve Conn. (Ind & Sol Only) | Compression nut and olive | Pipe union conn. nut and tail piece | |||
Expansion Vessel Size – 3/6 bar kit (ltr) | 24 / 35 | 35 / 50 | 50 / 80 | 80 / 100 | 100 / 150 |
Tundish | 1.25” | 1.25” | 1.25” | 1.25” | 1.5” |
ErP Energy Efficiency Class | C | C | C | C | C |
Standing Loss (W) | 92 | 102 | 115 | 121 | 124 |